Skip to main content

PMS 448

Shroud – Face & Neck, Wildland Firefighter's

NFES #
001274
Category
PPE
Updated
Storage and Shelf Life Checks
None

Initial Inspection/Disposal Criteria

  1. Inspect for holes, cuts, tears, or torn seams. Inspect for color change (yellow to white/pink) caused by exposure to heat. Dye sublimation is the result of heat baking the dye out of the fabric. Areas of fabric with dye sublimation do not affect the performance of the shirt. Charring (hard brittle fabric that will then form a hole) in association with sublimation will decrease the performance of the fabric and the item should be disposed of.
  2. Return to stock if item has no damage, is clean and in unused condition.
  3. Refurbish if item can be laundered and is repairable.
  4. Dispose of item if not economical to repair.

Refurbishing Procedures

A. Cleaning - DO NOT USE BLEACH TO CLEAN FABRIC.

  1. Follow the cleaning procedures described in the publication, Nomex®- Aramid Fiber -Laundering Guide (H71603).
    Additional information can be obtained by calling DuPont at 1–800–453–8527 or by writing:
    DuPont Advanced Fibers Systems
    Chestnut Run Plaza
    Laurel Run Building
    Wilmington, DE 19880-0705
  1. Abbreviated washing procedures from above publication:
    1. “Garments of NOMEX® should be washed separately from other articles to avoid contamination with lint of flammable fibers.”
    2. “Tests show that formulations designed for use at a temperature of l40 °F (60 °C) or less – such as high-surfactant, low-alkalinity products - adequately clean NOMEX® and provide the best fabric color retention.”
    3. “For heavily stained and oily garments of NOMEX®, a higher temperature wash formula may be required for adequate cleaning.”
    4. “Garments made of NOMEX® must be adequately rinsed to remove residual wash chemicals.”
    5.  “In some instances, tumble dry conditioning is the only finishing necessary for garments of NOMEX®.”
    6.  “…dry cleaning is an alternative method of removing heavy soil and may be preferable to repeated high-temperature washing.”
  2. If items are taken to vendor laundry facilities for refurbishment; ensure that they receive a copy of this refurbishment standard. The laundry facility must satisfy both--the requirements as set by the manufacturer specification and the agreement made with the local agency.

Nomex® Clothing Exposed to Poison Oak/Ivy/Sumac

RESEARCH

At the request of the National Support Cache Refurbishing Standards Committee, MTDC researched the practicality of laundering Nomex firefighting clothing that has been contaminated with urushiol oil (the allergen to which the body reacts) from poison oak/ivy/sumac exposure. Current cache practices range from normal washing procedures to disposal of shirts and pants that have known urushiol contamination.

A search of on-line sources didn’t produce any special care instructions beyond normal laundering. Some examples:

  • “All clothing should be laundered, and everything else that may be contaminated with urushiol should be washed thoroughly.” American Academy of Dermatology. 
  • “…be sure to wash your clothing promptly with detergent…” Mayo Clinic. 
  • “Washing clothes with ordinary laundry soap will remove urushiol.” Missouri Department of Conservation.

A phone conversation with Daniel Boelman, RN, BSN, Customer Service Manager with Zanfel Laboratories, Inc. also indicated no special treatment beyond normal laundering. (Zanfel produces a commercially available poison oak/ivy cream). Mr. Boelman recommended using vinyl gloves when handling contaminated clothing.

On 11/17/2008 the Forest Service filed a SAFENET Supplemental Corrective Action concerning poison oak reactions experienced by firefighters during the 2008 fire season in California. In that posting, it is recommended that “All clothing and equipment should be laundered immediately …A degreaser was recommended for helping to remove urushiol from clothing and equipment.”

RECOMMENDATION

MTDC recommends that fire clothing contaminated with urushiol oil be cleaned following normal Nomex laundering procedures. Extra care should be exercised when handling the contaminated clothing. Clearly labeled plastic bags should be used to separate contaminated clothing from other returned clothing. Commercial laundry personnel should wear long sleeves and vinyl gloves when handling contaminated clothing and dispose of any bags used for transporting the clothes to the laundering facility. As an extra precaution, supply cache and laundry workers could apply an over-the-counter skin-barrier product that contains bentoquatum (such as Ivy Block or Stokoguard) before handling contaminated clothing. Bentoquatum helps prevent urushiol from penetrating the skin. After exposure, workers’ clothes should be washed and gloves disposed of. 

B. Repair

  1. Mend holes, cuts, tears, burns, and torn seams by darning, patching, or by duplicating the original item.
  2. Replace damaged hook and pile fasteners with tape of same length, width, and quality.

C. Testing for Performance

  1. Inspect items after laundering to ensure all foreign matter and stains have been removed. If items fail second inspection spot treat problem areas or remove item from service.
  2. Test all replacement hook and pile fasteners after repairing.

D. Repackaging

  1. Lay the Shrouds with inside up, fold both sides towards middle, and fasten hook and pile fasteners.
  2. Recommended 20 EA in NFES #008064 carton (10” x 8” x 6”).

 

NWCG Latest Announcements

Updated NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515

Date: April 23, 2025
Questions?  Please contact:
Interagency Fire Unmanned Aircraft Systems Subcommittee

The NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515 standardizes processes and procedures for the interagency use of Unmanned Aircraft Systems (UAS), including pilot inspections and approvals. This updated publication provides the aviation community with standards to ensure UAS are used safely, effectively, and efficiently in support of fire management goals and objectives.

References:

NWCG Standards for Fire Unmanned Aircraft Systems Operations, PMS 515

NWCG National Interagency Aviation Committee

ETC Bulletin 25-001: Retrofitted Hot/Cold Beverage Kits - 2025 Field Season

Date: April 16, 2025
Questions?  Please contact:
Equipment Technology Committee

Due to spout failures and the associated risk of burn injuries, manufacturers have retrofitted the Hot/Cold Beverage Kits using a heat-shrinking band to secure the black spout at the insertion site. The updated kits feature a fluorescent label on each full kit assembly for easy identification. Catering units are encouraged to confirm the clear heat-shrinking bands are intact around each spout before filling.

ETC Bulletin 24-001 regarding Hot/Cold Beverage Kits has been archived and replaced by ETC Bulletin 25-001 for the 2025 season.

References:

NWCG Alerts

ETC-EB-25-001 Retrofitted Hot/Cold Beverage Kits

NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and Next Generation Position Task Book for Basic Faller Are Now Available

Date: April 14, 2025
Questions?  Please contact:
Hazard Tree and Tree Felling Subcommittee

The updated NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212, and NWCG Position Task Book for Basic Faller (FAL3), PMS 311-19 are now available.

The NWCG Standards for Wildland Fire Chainsaw Operations, PMS 212 includes position standards designed to be used in conjunction with the Next Generation Position Task Book (Next Gen PTB). The Next Gen PTB for Basic Faller (FAL3) includes an evaluation guide with suggested rating elements to consider when assessing trainees.

References:

NWCG Standards For Wildland Fire Chainsaw Operations, PMS 212

NWCG Position Task Book for Basic Faller (FAL3), PMS 311-119

NWCG Basic Faller (FAL3)

RMC Memo 25-01: Summary of Updates to Safety Officer Positions

Date: April 9, 2025
Questions?  Please contact:
RMC Member Eric Fransted

The Risk Management Committee (RMC) serves as the position steward for all Safety Officer incident positions and continues to improve position standards, training, and naming conventions. The implementation of Complex Incident Management (CIM) required changes to position titles. RMC collaborated with the NWCG Incident Position Standards Committee (IPSC) to propose and implement these updates. 

References:

RMC Memo 25-01: Summary of Updates to Safety Officer Positions 

NWCG Position Catalog