Storage and Shelf Life Checks
Yes
Storage and Shelf Life Procedure
1. Store in secured (no-smoking) area. Tanks will vent fumes when they get hot. Store out of direct sun.
2. Refer to Forest Service Health & Safety Handbook, OSHA, NFPA, and local direction.

Initial Inspection/Disposal Criteria

  1. Check for rust, dents, punctures, broken valves, and weak valve handle. Verify handle type to ensure that tank meets current specifications for “OPD” valve
  2. Confirm test date on propane tank. See link to “Requalification Guidance for Propane Cylinders” under Reference.
  3. Return to stock if unused and recertification is valid.
  4. Refurbish item if tank is undamaged.
  5. Dispose of item if unable to refurbish.

Refurbishing Procedures

A. Testing for performance

  1. Apply soapy water to valve area, watch for bubbles indicating leaks.
  2. If leaks are detected, tag immediately for repair or remove from service.
  3. Safely dispose of tank contents per local HAZMAT disposal policy. Deliver tank to local LPG provider for tank testing, repairs, or disposal.

B. Cleaning

  • Power wash tank and let dry.

C. Repair

  1. Replace any broken handles.
  2. Ensure warning labels are visible and replace as necessary. Cylinders must be marked in accordance with NFPA 704 when used in industrial or commercial applications using labels: HZ-116 or CYL 3 in 1.
  3. A painted stencil or decal reading “NOT FOR INDOOR USE” must be located in a highly visible location on the propane tank with red lettering at least 3/4 inches tall in size.
  4. Install plastic cap or plug in valve opening if missing.
  5. All other repair will be done by and authorized facility.
  6. Follow local cache protocols for refilling empty tanks.

D. Repackaging

  1. Ensure valve is in the “OFF” position before transporting.
  2. Place on pallets and secure with wrap or ties to ensure tanks do not fall or tip over. 

 

NWCG Latest Announcements

LMC Equipment Bulletin 26-001: Aquatic Invasive Species – Seasonal Reminder for Mussels

Date:  July 30, 2026
Questions? 
Please contact: Equipment and Technology Subcommittee

The Logistics and Equipment Management Committee (LMC) issued Equipment Bulletin 26-001: Aquatic Invasive Species - Seasonal Reminder for Mussels, reminding the wildland fire community that aquatic mussels continue to be a problem. Mussels rapidly colonize hard and soft surfaces, including aquatic plants and fire equipment, clogging pipes, fouling motors, disrupting water systems, and impacting native species.

To help prevent their spread, fire personnel must follow the decontamination procedures outlined in the NWCG Guide to Preventing Aquatic Invasive Species Transport by Wildland Fire Operations, PMS 444. Additionally, report any sightings immediately to your Lead Resource Advisor and include clear, close-up photos (with a pen or your hand for size reference) and location details.”

Read the complete LMC Equipment Bulletin 26-001, to learn more. 

References:

NWCG Alerts

LMC Equipment Bulletin 26-001: Aquatic Invasive Species - Seasonal Reminder for Mussels

NWCG Guide to Preventing Aquatic Invasive Species Transport by Wildland Fire Operations, PMS 444

Intermediate Faller (FAL2) Position Task Book Update

Date:  July 24, 2026
Questions? 
Please contact: Tree Felling Subcommittee

NWCG Operations Management Committee (OMC) has issued an update to the NWCG Position Task Book for Intermediate Faller (FAL2), PMS 311-91. To ensure clarity for both trainees and evaluators, the updated FAL2 Position Task Book (PTB) explicitly states who is authorized to sign off on your tasks:

“Evaluators must be qualified as a FAL2, or an Advanced Faller (FAL1).”

If you are currently working out of a previously published version of the FAL2 PTB, you do not need to restart. However, OMC highly encourages you to take the following step to prevent any confusion in the field:

  • Print and replace the updated evaluator information page (page 2) in your current physical PTB.

References:

Intermediate Faller (FAL2) Position Page

RMC Memo 26-01: Transition Plan for Implementing Updates to Intermediate Faller (FAL2) Position Qualifications

NWCG Position Task Book for Intermediate Faller (FAL2), PMS 311-91

Equipment Advisory 26-001: Potential Front Driveline Joint Failure on 2018 and Earlier Ram Pickups

Date:  July 10, 2026
Questions? 
Please contact: Equipment and Technology Subcommittee

The Logistics/Equipment Management Committee (LMC) has released Equipment Advisory 26-001: Potential Front Driveline Joint Failure on 2018 and Earlier Ram Pickups. This advisory highlights multiple U.S. Forest Service regions reporting front driveline joint failure incidents.

This advisory recommends firefighters and fire managers to: 

  • Follow all Ram-issued inspection, maintenance, and service guidance for front driveline joints. 
  • Consider installing a driveline loop. 
  • Coordinate with fleet managers and service providers to determine the most appropriate driveline loop kit for each pickup.

For further details, please refer to the complete advisory.

References:

Equipment Advisory 26-001: Potential Front Driveline Joint Failure on 2018 and Earlier Ram Pickups

Technical Service Bulletin: 03-002-21

NEW! NWCG Standard Operating Procedures, PMS 900

Date:  July 9, 2026
Questions? 
Please contact: NWCG Staff

NWCG is excited to announce the publication of the NWCG Standard Operating Procedures, PMS 900.

The new publication establishes general, consistent, and uniform standards for conducting business with the National Wildfire Coordinating Group.

References:

NWCG Standard Operating Procedures, PMS 900