Skip to main content

Can – 1 GL (3.8L), Gas, Safety, Vented

NFES #
000350
Category
Fuel Handling
Updated
Storage and Shelf Life Checks
Yes
Storage and Shelf Life Procedure
If stored outside protect from rain, snow or any form of moisture.

Initial inspection/Disposal Criteria

  1. Inspect for fuel or mixes and dispose of properly.
  2. Inspect for rust that has pitted, is flaking or is lifting the interior surface and determine extent as some “flash rust” maybe present.
  3. Inspect for leaks or separation along seams.
  4. Inspect all threads on nozzles for serviceability.
  5. Inspect spring closure devices to be sure they are functioning properly.
  6. Inspect for can integrity and uniformity, i.e. collar crushed, large dents, punctures, modifications.
  7. Inspect all cotter keys and pins.
  8.  Ensure that containers are properly marked and labeled.
  9. Ensure spark arrester screen is present, replace as necessary.
  10. Return to stock if item shows no signs of use and passes visual inspection.
  11. Refurbish if item has been used and/or damage is repairable.
  12. Dispose of item if damage is found and it cannot be repaired.

Refurbishing Procedures

A. Cleaning

  1. Drain all existing fuel.
  2. With pressure washer and detergent wash outside of container.
  3. Use a rag and air hose or some means to dry the interior of the container.
  4. Turn upside down with lids off or open to dry.
  5. Spray inside of can lightly with WD-40 or similar product.

B. Repair

  1. Replace any defective cotter key or pins.
  2. Wipe down outside of container and repaint if necessary. 
  3. Ensure container is properly marked and labeled. Color requirement for the cans are red with yellow markings. Label shall be FLAMMABLE LIQUID. Markings are dependent on fuel type and can be accomplished using NFES tags #000805, #000802, #000803, #000801.
  4. Ensure fuel geyser warning label is present and legible near spout area. Reference cache memo 17-2 below.
  5. Secure proper spout to top of can, if applicable.

C. Tests for Performance

  • None

D. Repackaging

  • None

 

NWCG Latest Announcements

NEW! NWCG Wildland Urban Interface Mitigation Field Guide, PMS 053

Date: March 12, 2025
Contact: Wildland Urban Interface Mitigation Committee

The NWCG Wildland Urban Interface Mitigation Field Guide, PMS 053 provides mitigation practitioners at all experience levels with recommendations on the most effective and efficient ways to accomplish mitigation work in communities at risk to wildfire damage or destruction. The content in this guide was written in coordination with the NWCG Standards for Mitigation in the Wildland Urban Interface, PMS 052.

References:

NWCG Wildland Urban Interface Mitigation Field Guide, PMS 053 

Updated, NWCG Standards for Wildland Fire Module Operations, PMS 430

Date: March 11, 2025
Contact: Fire Use Subcommittee
Wildland Fire Module Unit

The NWCG Standards for Wildland Fire Module Operations, PMS 430 standardizes procedures and expectations for Wildland Fire Modules (WFMs). These standards are to be used by staff, supervisors, specialists, and technicians for planning, administering, and conducting WFM operations. These standards will also be used as a measure of WFM qualifications, capabilities, and expected performance, for both Type 1 and Type 2 WFMs.

References:

NWCG Standards for Wildland Fire Module Operations, PMS 430

NEW! NWCG Standards for Airtanker Operations, PMS 514

Date: March 7, 2025
Contact: National Interagency Aviation Committee

The NWCG Standards for Airtanker Operations, PMS 514 establishes the standards for dispatching, utilizing, and coordinating airtankers on interagency wildland fires. These standards should be used in conjunction with the NWCG Standards for Aerial Supervision (SAS), PMS 505, NWCG Standards for Airtanker Base Operations (SABO), PMS 508, and any applicable agency plans.

References:

NWCG Standards for Airtanker Operations, PMS 514

Incident Position Standards and Next Gen Position Task Books Now Available for Dispatch Incident Positions

Date: March 5, 2025
Contact: National Coordination System Committee

NWCG is excited to announce that Incident Position Standards and Next Generation Position Task Books are now available for all six Dispatch positions:

  • Aircraft Dispatcher
  • Expanded Dispatch Coordinator
  • Expanded Dispatch Recorder
  • Expanded Dispatch Supervisory Dispatcher
  • Expanded Dispatch Support Dispatcher
  • Initial Attack Dispatcher

The Performance Support Packages for these positions, including the Expanded Dispatch Job Aid, J-601 and the Initial Attack and Aircraft Dispatcher Job Aid, J-602, were developed as part of the Incident Performance and Training Modernization (IPTM) effort. These resources support trainees, qualified personnel, and evaluators in their roles.

Any changes to qualification pathways will take effect with the next update of the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1.

References:

NWCG Aircraft Dispatcher Position Page 

NWCG Expanded Dispatch Coordinator Position Page 

NWCG Expanded Dispatch Recorder Position Page 

NWCG Expanded Dispatch Supervisory Dispatcher Position Page 

NWCG Expanded Dispatch Support Dispatcher Position Page 

NWCG Initial Attack Dispatcher Position Page 

NWCG Job Aids