Skip to main content

PMS 448

Berm – Containment, 55 GL (1 to 4 drums)

NFES #
000692
Category
Miscellaneous
Updated
Storage and Shelf Life Checks
None

Initial Inspection/Disposal Criteria

  1. Inspect for dirt, debris, fuel, and other liquids which may be present and/or soiled absorbent cloth.  Dispose of soiled absorbent cloth according to local hazardous materials standards.
  2. Must have foam bumper around the outer edge (see photo below).  The lay flat style is being removed from service.
  3. Inspect for torn or missing tie down grommets, holes, rips, or tears that are large or too numerous. Repair if holes or tears are 1 inch or less, or a combination of 3 holes with a combined length of 1.5 inches.
  4. Return to stock if item shows no signs of use and passes initial inspection.
  5. Refurbish if damage detected is repairable.
  6. Dispose of item if damage is determined to be unrepairable.

Refurbishing Procedures

A. Cleaning

  1. Clean with pressure washer to remove matter such as mud, dirt, and grease.
  2. Use a solution of mild detergent and water to remove grease with an absorbent cloth.
  3. Dispose of saturated cloth according local hazardous materials standards.
  4. Wipe dry or let air dry.

B. Repair

  1. Hold up to strong light or sun to locate holes.  Holes or tears 1 inch or less or a combination of 3 holes with a combined length of 1.5 inches are acceptable for repair.
  2. With suitable cleaner, apply vinyl adhesive to both surfaces, i.e., patch and berm.
  3. Let dry till tacky.
  4. Place patch on damaged area and apply pressure with roller or suitable device for at least 1 minute.
  5. Let berm sit flat and dry.
  6. Vinyl welding with patch material like in thickness and color of berm material is acceptable for repair.  Follow instructions or established local procedures for completing vinyl welding repairs.

C. Testing for Performance

  • None

D. Repackaging

  1. Roll berm and band for storage. (see photos below for details)
  2. Suggested packaging is 1 each in NFES #000513 carton (36” x 24” x 17”).

EXAMPLE ROLL FOR PLACING IN #000645 CARTON

Fold left side to center.

Fold right side to center.

Roll up folded berm.

Tie rolled berm with twine.

Place rolled and bound berm in box.

 

 

NWCG Latest Announcements

Updated NWCG Standards for Water Scooping Operations, PMS 518

Date: December 19, 2024
Contact: Water Scooper Operations Unit

The NWCG Standards for Water Scooping Operations, PMS 518 establishes the standards for dispatching, utilizing, and coordinating water scooping aircraft on interagency wildland fires. These standards should be used in conjunction with the NWCG Standards for Aerial Supervision (SAS), PMS 505, and any local, state, or geographic/regional water scooping plans.

References:

NWCG Standards for Water Scooping Operations, PMS 518

Updated NWCG Standards for Aerial Supervision, PMS 505

Date: December 19, 2024
Contact: Interagency Aerial Supervision Subcommittee

The Interagency Aerial Supervision Subcommittee has updated the NWCG Standards for Aerial Supervision, PMS 505. PMS 505 establishes standards for aerial supervision operations for national interagency wildland fire operations. 

References:

NWCG Standards for Aerial Supervision, PMS 505

New Job Aids Available: Packing Lists for Wildland Fire Fireline Personnel and Support Staff, J-101 and J-102

Date: December 3, 2024
Contact: NWCG TRAINING

Two new job aids are now available: Packing List for Wildland Fire Fireline Personnel, J-101 and Packing List for Wildland Fire Support Personnel, J-102, should serve as a baseline for items needed on a wildland fire assignment. These lists will help personnel prepare for a 14 to 21-day assignment on the fireline or in a support role.

References:

Job Aid Catalog

NWCG Packing List for Wildland Fire Fireline Personnel, J-101

NWCG Packing List for Wildland Fire Support Staff, J-102

NWCG Equipment Technology Committee Releases Safety Warning: 24-001 Stihl Chainsaw Toolless Fuel Cap Spill Prevention

Date: November 14, 2024
Contact: Equipment Technology Committee

The Equipment Technology Committee (ETC) has released Safety Warning: 24-001 Stihl Chainsaw Toolless Fuel Cap Spill Prevention. Misaligned toolless fuel caps on Stihl chainsaws have led to recurring fuel spillage, fuel ignition, and burn injuries during wildland fire management operations.

This Safety Warning is intended to highlight the details and recommended procedures for the installation of a Stihl chainsaw toolless fuel cap, as well as how to identify and correct a misaligned, damaged, or broken fuel cap to help prevent fuel spillage.

References:

NWCG Safety Warning: 24-001 Stihl Chainsaw Toolless Fuel Cap Spill Prevention

Advertencia de equipos 24-001: Prevención de derrames de la tapa de combustible sin herramientas de la motosierra Stihl

NWCG Alerts