Updated
Storage and Shelf Life Checks
Yes
Storage and Shelf Life Procedure
Inspect annually for service life compliance.

Initial Inspection/Disposal Criteria

Note:   National Incident Support Caches consider helmets a consumable item.  Helmets returned to caches removed from their original packaging will be considered used and will not be refurbished or reissued.  Helmets that have been issued but not removed from their original packaging will be subject to the Wildland Firefighter’s Helmet Serviceability Guide and Inspection process below to determine serviceability.

 

  1. Wildland Firefighter’s Helmet Serviceability Guide:
    1. Has it been more than 10 years since the helmet’s date of manufacture (DOM)? If yes then remove from service.  If it is less than 10 years since DOM, Inspect the helmet.
    2. Helmet is less than 10 years from DOM:  Inspect the helmet using inspection criteria in #2.  Does the helmet pass inspection?  If yes, return to stock.  If no, remove from service.
  2. Inspection

The shell should be inspected routinely for dents, cracks, nicks, gouges, and any damage that might reduce protection. Any helmet that shows signs of worn or damaged parts should be removed from service immediately.

The shell material may be degrading if the shell becomes stiff, brittle, faded, or appears dull or chalky. With further degradation, the shell's surface may flake or delaminate.  A hardhat should be replaced at the first sign of any of these conditions.

  1. Compress the shell from both sides about 1 inch with your hands and release the pressure without dropping the shell.  The shell should return to its original shape quickly, exhibiting elasticity.  Compare the elasticity with that of a new shell.  If the shell being tested does not have as much elasticity as the new shell, or if the shell cracks, it should be replaced immediately.
  2. Inspect the suspension system closely for cracks, cut or frayed shell straps, torn headband or size adjustment slots, loss of pliability, or other signs of wear.  Remove and replace any suspension that is damaged.
  3. Inspect for cracks, chips in shell, scuff marks and discoloration, and if so dispose of.
  4. Ensure that all attachment clips are present (chin strap, headlamp, liner, neck and face shroud).
  5. Inspect for markings, drawings or labels, if any dispose of.
  6. All certification labels (ANSI, etc.) must be present in helmet, if not dispose of.
    See also: Inspection Guidelines: From Your Hardhat: Inspection and Maintenance 0267 2331. Missoula, MT: U.S. Department of Agriculture, Forest Service, Missoula Technology and Development Center. 4p.  
  7. Return to Stock if helmet complies with the Wildland Firefighter’s Helmet Serviceability Guide and passes initial inspection.
  8. Refurbish helmet if it complies with the Wildland Firefighter’s Helmet Serviceability Guide the passes initial inspection but requires cleaning and or repair.
  9. Dispose of helmet if it fails inspection or the Wildland Firefighter’s Helmet Serviceability Guide.

 

Refurbishing Procedures

A.  Cleaning

  • Wash with soap and water, rinse, and air dry.

B.  Repair

  1. Replace with new liner and new chin strap.
  1. Attach front 2 suspension clips to helmet to ensure proper fit.
  2. Add or replace reflective strips.
  3. Add or replace Velcro strips
  4. Velcro strips 1½” x 2¼” and placed at center at rear of helmet and 9½” around curvature of helmet on each side.
  5. The adhesive used shall be approved by the manufacturer for use on the helmet.

 

C. Testing for performance

  • None

D. Repackaging

  • Local cache option.

 

Reference

Velcro available from:
Textrol Systems Inc.,
435 Meadow Lane, Carlstadt, NJ 07072
Phone: 800–624–8746
Part #193973 (Part B-male)

ETC helmet serviceability guide showing action needed.

This link will take you to the etc-determine-dom.pdfThis link will take you to the etc-helmet-notice.pdf

 

 

NWCG Latest Announcements

Intermediate Faller (FAL2) Position Task Book Update

Date:  July 24, 2026
Questions? 
Please contact: Tree Felling Subcommittee

NWCG Operations Management Committee (OMC) has issued an update to the NWCG Position Task Book for Intermediate Faller (FAL2), PMS 311-91. To ensure clarity for both trainees and evaluators, the updated FAL2 Position Task Book (PTB) explicitly states who is authorized to sign off on your tasks:

“Evaluators must be qualified as a FAL2, or an Advanced Faller (FAL1).”

If you are currently working out of a previously published version of the FAL2 PTB, you do not need to restart. However, OMC highly encourages you to take the following step to prevent any confusion in the field:

  • Print and replace the updated evaluator information page (page 2) in your current physical PTB.

References:

Intermediate Faller (FAL2) Position Page

RMC Memo 26-01: Transition Plan for Implementing Updates to Intermediate Faller (FAL2) Position Qualifications

NWCG Position Task Book for Intermediate Faller (FAL2), PMS 311-91

Equipment Advisory 26-001: Potential Front Driveline Joint Failure on 2018 and Earlier Ram Pickups

Date:  July 10, 2026
Questions? 
Please contact: Equipment and Technology Subcommittee

The Logistics/Equipment Management Committee (LMC) has released Equipment Advisory 26-001: Potential Front Driveline Joint Failure on 2018 and Earlier Ram Pickups. This advisory highlights multiple U.S. Forest Service regions reporting front driveline joint failure incidents.

This advisory recommends firefighters and fire managers to: 

  • Follow all Ram-issued inspection, maintenance, and service guidance for front driveline joints. 
  • Consider installing a driveline loop. 
  • Coordinate with fleet managers and service providers to determine the most appropriate driveline loop kit for each pickup.

For further details, please refer to the complete advisory.

References:

Equipment Advisory 26-001: Potential Front Driveline Joint Failure on 2018 and Earlier Ram Pickups

Technical Service Bulletin: 03-002-21

NEW! NWCG Standard Operating Procedures, PMS 900

Date:  July 9, 2026
Questions? 
Please contact: NWCG Staff

NWCG is excited to announce the publication of the NWCG Standard Operating Procedures, PMS 900.

The new publication establishes general, consistent, and uniform standards for conducting business with the National Wildfire Coordinating Group.

References:

NWCG Standard Operating Procedures, PMS 900

Quarter Four Materials for the 2025-2026 Wildland Fire Leadership Campaign Now Available

Date:  July 8, 2026
Questions? 
Please contact: Leadership Development Subcommittee

NWCG is excited to announce that Fourth Quarter materials for the 2025/2026 Wildland Fire Leadership Campaign are now available. This annual initiative offers all students of leadership and wildland fire management an opportunity to engage with essential leadership skills and knowledge needed to lead effectively in dynamic environments.

Quarter Four materials focus on Leadership Level 4: Leader of Leaders (Provide Direction). Leadership Level 4 is where you are setting the conditions for others to do things well, even when you are not present. This quarter focuses on equipping experienced leaders with skills to provide direction, build trust across teams, and foster strong decision making. 

References:

2025/2026 NWCG Leadership Campaign - Leadership Levels

Wildland Fire Leadership Development Program

Leadership Development Subcommittee