Skip to main content

Tank – Folding, 1000 GL (3785.4L) w/Frame

NFES #
000661
Category
Water Handling
Updated
Storage and Shelf Life Checks
None

Initial Inspection/Disposal Criteria

  1. Inspect frame for broken or bent parts, cracks or separations in the welds. Inspect the liner for pin holes, tears, or rips and missing grommets. Inspect for frayed or damaged rope or missing nylon ties securing liner to frame.
  2. Return to stock if item is clean and in unused condition.
  3. Refurbish item if able to clean and repair. For repairs requiring materials or skills not found at the local cache, contact manufacturer to determine if it is economically feasible to have manufacturer repair tank.
  4. Dispose of item if damages are not economically feasible to repair.

Refurbishing Procedures

A. Cleaning

  1. Clean tank liner and frame, inside and outside, with soapy water and a brush or high-pressure wash and rinse.
  2. Allow to air dry on both sides.

B. Repair

Frame

  1. Straighten frame.
  2. Weld all cracked or broken welds on frame.
  3. Remove rust. Paint as needed.
  4. Lubricate hinges with appropriate lubricant.

Liner

  1. Patch any hole or tears. Small pin hole can be repaired with manufacturer recommended TEARAID® Type B or other similar material recommended by the tank manufacturer. Larger holes should be patched with material recommended by the manufacturer utilizing a vinyl welding process. For extremely large holes, contact the tank manufacturer for recommended repair or replacement options.
  2. Replace any missing grommets. If two or more grommets are missing in succession and new grommets cannot be installed, replace liner.
  3. The use of cable ties or ¼” nylon rope is recommended for securing the liner to the frame. Ensure that ties or ropes are secure. Replace or tighten as necessary. When using cable ties, use one per grommet and utilize large cable ties at corner and midpoints. Use smaller ties in all other grommets. When using rope, secure one end to the frame. Using a lacing motion, go through the grommet, over the frame and through the next grommet. Continue this motion until entire liner is attached to frame. Secure end.
  4. Stencil correct NFES # of item on side of tank if missing or unreadable.

C. Testing for performance

  1. Verify hinges operate smoothly.
  2. Check all patches to insure they are secure and there are no loose edges.

D. Repackaging

  1. Fold the tank ensuring that liner is not pinched during process. Only a minimum, if any, amount of liner is to extend outside the metal frame.
  2. Band 1,000GL tank near ends, Band 1,500GL tank near ends and in the middle.
  3. Secure on pallet.

 

NWCG Latest Announcements

Updated, NWCG Standards for Wildland Fire Module Operations, PMS 430

Date: March 11, 2025
Contact: Fire Use Subcommittee
Wildland Fire Module Unit

The NWCG Standards for Wildland Fire Module Operations, PMS 430 standardizes procedures and expectations for Wildland Fire Modules (WFMs). These standards are to be used by staff, supervisors, specialists, and technicians for planning, administering, and conducting WFM operations. These standards will also be used as a measure of WFM qualifications, capabilities, and expected performance, for both Type 1 and Type 2 WFMs.

References:

NWCG Standards for Wildland Fire Module Operations, PMS 430

NEW! NWCG Standards for Airtanker Operations, PMS 514

Date: March 7, 2025
Contact: National Interagency Aviation Committee

The NWCG Standards for Airtanker Operations, PMS 514 establishes the standards for dispatching, utilizing, and coordinating airtankers on interagency wildland fires. These standards should be used in conjunction with the NWCG Standards for Aerial Supervision (SAS), PMS 505, NWCG Standards for Airtanker Base Operations (SABO), PMS 508, and any applicable agency plans.

References:

NWCG Standards for Airtanker Operations, PMS 514

Incident Position Standards and Next Gen Position Task Books Now Available for Dispatch Incident Positions

Date: March 5, 2025
Contact: National Coordination System Committee

NWCG is excited to announce that Incident Position Standards and Next Generation Position Task Books are now available for all six Dispatch positions:

  • Aircraft Dispatcher
  • Expanded Dispatch Coordinator
  • Expanded Dispatch Recorder
  • Expanded Dispatch Supervisory Dispatcher
  • Expanded Dispatch Support Dispatcher
  • Initial Attack Dispatcher

The Performance Support Packages for these positions, including the Expanded Dispatch Job Aid, J-601 and the Initial Attack and Aircraft Dispatcher Job Aid, J-602, were developed as part of the Incident Performance and Training Modernization (IPTM) effort. These resources support trainees, qualified personnel, and evaluators in their roles.

Any changes to qualification pathways will take effect with the next update of the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1.

References:

NWCG Aircraft Dispatcher Position Page 

NWCG Expanded Dispatch Coordinator Position Page 

NWCG Expanded Dispatch Recorder Position Page 

NWCG Expanded Dispatch Supervisory Dispatcher Position Page 

NWCG Expanded Dispatch Support Dispatcher Position Page 

NWCG Initial Attack Dispatcher Position Page 

NWCG Job Aids 

Incident Position Standards and the Next Generation Position Task Books Now Available for DMOB, DOCL, and RESL

Date: February 28, 2025
Contact: Incident Operations Subcommittee

NWCG is excited to announce that Incident Position Standards and the Next Generation Position Task Books are now available for Demobilization Unit Leader (DMOB), Documentation Unit Leader (DOCL), and Resources Unit Leader (RESL).

The Performance Support Packages for these positions, including a job aid for RESL, were developed as part of the Incident Performance and Training Modernization (IPTM) effort. These resources support trainees, qualified personnel, and evaluators in their respective roles.

Any changes to qualification pathways will take effect with the next update of the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1.

References:

NWCG Demobilization Unit Leader Position Page 

NWCG Documentation Unit Leader Position Page 

NWCG Resources Unit Leader Position Page