Skip to main content

Valve – Shut Off, Zinc, Ball, 3/4” NH

NFES #
000738
Category
Water Handling
Updated
Storage and Shelf Life Checks
None

Initial Inspection/Disposal Criteria

  1. Inspect for obvious damage including burrs and thread damage, gaskets missing or damaged, a female collar that must turn freely if applicable, and inspect for damage caused by fire exposure.
  2. Return to stock if item is clean, passes inspection and is in unused condition.
  3. Refurbish if deficiencies are discovered during the inspection process and item requires cleaning.
  4. Dispose of item if damages are not repairable or item has sustained damage caused by fire.

Refurbishing Procedures

A. Cleaning

  1. Clean in a mild detergent with brush and scouring pad or use parts washer or high pressure wash to remove foreign matter such as mud, dirt or grease. Rinse thoroughly.
  2. Do not soak for extended periods of time as detergent will corrode the metal.
  3. Stand upright with barrel in open position to drain water and dry.

B. Repair

  • Replace missing or damaged gaskets or components that are serviceable.

C. Testing for Performance

  1. Install valve on test pump.
  2. Turn on water to pump and open valve to expel air then close valve.
  3. Turn on pump
  4. NFES #001201 and NFES #001207 test at 300 PSI for 3 minutes.
  5. NFES #000835 and NFES #000738 test at 100 PSI for 3 minutes.
  6. Inspect for leaks around the gasket and at the handles while on test pump.
  7. If valve leaks, repair as necessary or dispose of through local procedures.
  8. Retest after repairs are made.

D. Repackaging

  1. Ensure item is completely dry prior to packaging.
  2. Packaging:
    • Use NFES #008066 carton (12” x 9” x 10”) for the following: NFES #001201, #001207 standard pack of 20 EA per carton. 
    • Use NFES #008064 carton (10” x 8” x 6”) for the following: NFES #000835 standard pack of 50 EA per carton. 
    • Use NFES #008076 carton (8” x 4” x 4”) for the following: NFES #000738 standard pack of 10 EA per carton.

 

NWCG Latest Announcements

2024 Paul Gleason Award Winners Announced

Date:  March 13, 2026
Questions? 
Please contact: Leadership Committee

The NWCG Leadership Committee is proud to announce the recipients of the 2024 Paul Gleason "Lead By Example" awards. Award categories include Initiative and Innovation, Mentoring and Teamwork, Motivation and Vision, as well as a Lifetime Achievement Award.

Congratulations to the awardees:

  • Justin Baxter, National Unmanned Aerial System (UAS) Operations Specialist, with the U.S. Forest Service — Initiative and Innovation
  • Kelly Woods, Director of the Wildland Firefighting Lessons Learned Center — Mentoring and Teamwork
  • Doug Booster, Instructor, ProHealth Net, Inc. — Motivation and Vision
  • Pam McDonald, Writer-Editor for the National Interagency Fire Center — Lifetime Achievement Award

References:

Paul Gleason Lead By Example Award

Wildland Fire Leadership Development Program (WFLDP)

Leadership Committee

NEW! S-231, Engine Boss Course Available Now

Date:  March 6, 2026
Questions? 
Please contact: Incident Operations Subcommittee

NWCG is pleased to announce the new S-231, Engine Boss (Single Resource) course is now available on the Wildland Fire Learning Portal (WFLP). Developed through the Incident Performance and Training Modernization (IPTM) effort, this training supports individuals working towards Engine Boss, Single Resource (ENGB) incident qualifications. 

This is a performance-based instructor-led training (ILT) that focuses on the application of ENGB responsibilities during wildland fire operations, emphasizing readiness, information gathering, risk management, engine tactics, and Wildland Urban Interface (WUI) operations. Trainees apply these skills through scenario-based group work and an optional field day that reinforces hands-on engine operation tasks. 

References:

S-231, Engine Boss (Single Resource) (Instructor-led)

NWCG Engine Boss, Single Resource (ENGB) Position Page

Wildland Fire Learning Portal

NWCG Celebrates 50 Years!

Date:  March 6, 2026
Questions? 
Please contact: NWCG Executive Secretary

NWCG is proud to celebrate 50 years of service to the wildland fire community. Beginning in 1976 with an interagency agreement between the Department of Interior and Department of Agriculture, NWCG has grown to include additional member agencies and is recognized as the standard-setting leader in wildland fire operations.

To honor where we’ve been and highlight where we are going, the NWCG team has created a video showcasing our history and accomplishments. The video is now available on the NWCG website.

References:

NWCG 50 Year Anniversary Video

NEW! S-131, Firefighter Type 1 Course Available Now

Date:  March 6, 2026
Questions? 
Please contact: Incident Operations Subcommittee

NWCG is pleased to announce the new S-131, Firefighter Type 1 course is now available on the Wildland Fire Learning Portal (WFLP). Developed through the Incident Performance and Training Modernization (IPTM) effort, this course is a performance-based instructor-led training (ILT) that focuses on the application of situational awareness and decision making, building on the knowledge and concepts introduced in previous required courses. Using a threaded fictitious fire, each unit focuses on a performance-based activity in which students practice applying their decision-making and problem-solving skills.

The S-131, Firefighter Type 1 course is required for individuals seeking qualifications to be a Firefighter Type 1 (Squad Boss) (FFT1) or an Incident Commander Type 5 (ICT5).

References:

S-131, Firefighter Type 1 (Instructor-led)

NWCG Firefighter Type 1 (Squad Boss) Position Page

NWCG Incident Commander Type 5 Position Page

Wildland Fire Learning Portal