Skip to main content

National Fuel Geyser Awareness

Fuel Geyser Triangle with Fuel, Heat, and Pressure as the sides.

Click Here to Report Fuel Geyser Incidents

 

What is a fuel geyser?

The rapid and energetic expulsion of heated fuel in a closed container when a fuel container is quickly depressurized. Heat and agitation causes the pressure increase. A delayed fuel geyser can occur after the fuel container is opened.

 

 

What does a fuel geyser look like?

Why is this important to me?

Over the last two years three significant burn injuries have occurred on prescribed fire and wildland fire incidents. Many additional fuel geyser incidents have been reported. These events happen frequently and have the potential to harm users of power equipment and people refueling power equipment. If you experience or have experienced a fuel geyser please report it.

Incident Reports

The following reports contain incidents where fuel geysers have occurred:

What do I need to know to protect myself?

Fuel geysers can happen anytime when there is fuel, heat & pressure from small gasoline-powered engines, chainsaws, leaf blowers, portable pumps, even when opening fuel transport containers.

Fuel geysers have resulted in injury when sprayed fuel and vapor ignite.

Appropriate precautions when there is fuel, heat & pressure, may prevent significant burns in the event of fuel spray.

  • Always assume fuel tanks and fuel containers are pressurized.
  • Ensure the cap is correctly secured.
  • Always check fuel levels before opening the fuel tank or filler cap. Fuel levels greater than ½ tank may geyser.
  • Move at least 20 feet or more from any heat source. 
  • For safety cans with pour spouts, direct potential spray away.
  • Cover the cap with a rag to contain potential fuel geyser spray.
  • Be extra vigilant when equipment is running poorly with fuel levels above ½ tank.
  • Start the saw at least 10 feet from the fueling area.
  • Do not use fuel older than one month.

If the equipment is running poorly or vapor lock is suspected:

  1. Do not open fuel cap. Relieving the pressure does not alleviate a “vapor lock” equipment.
  2. Check fuel level through the tank or use the bar oil level to gage fuel level.
  3. If fuel level is over ½ full, DO NOT open the tank.
  4. Allow the equipment to thoroughly cool. This could take over 45 minutes.
  5. When the equipment is cool, restart the equipment.

It’s YOUR job to protect yourself and others. Know how to handle your equipment to avoid fuel geysers anytime there is fuel, heat & pressure.

What should I do If I experience a fuel geyser?

Please REPORT every fuel geyser incident you experience!

The information you provide our engineers can mean the difference between one of our employees getting injured or not.

To report an incident go to Fuel Geyser Incident Reporting Form.

Location of Incidents

View a map of fuel geysering incidents and fuel requirements.

Videos

Video: USFS - Fuel Geysering: Predictable?

 

 

NWCG Latest Announcements

The Next Generation Position Task Book and Incident Position Standards are now available for Safety Officer, Field (SOFF)

Date: July 26, 2024
Contact: Risk Management Committee 

NWCG is excited to announce that the NWCG Incident Position Standards for Safety Officer, Field, PMS 350-81 and NWCG Position Task Book for Safety Officer, Field (SOFF), PMS 311-81 are now available.

The Safety Officer, Field (SOFF) is responsible for monitoring operations on an incident from a risk management perspective to provide for the welfare of incident resources and the public. The new Incident Position Standards and Next Generation Position Task Book are developed through the Incident Performance and Training Modernization (IPTM) effort.

References:

NWCG Safety Officer, Field (SOFF) Position

NWCG Incident Position Standards for Safety Officer, Field, PMS 350-81

NWCG Position Task Book for Safety Officer, Field (SOFF), PMS 311-81

Updated NWCG Standards for Electronic Documentation (eDoc), PMS 277

Date: July 25, 2024
Contact: Incident Planning Subcommittee 

The Incident Planning Subcommittee has updated the NWCG Standards for Electronic Documentation (eDoc), PMS 277.

The NWCG Standards for Electronic Documentation (eDoc) establishes the standards for collection and retention of records on wildland fires. This July 2024 update will provide incident management teams the most current standards required to maintain incident records and submit them to host units at the close of an incident.

References:

NWCG Standards for Electronic Documentation (eDoc), PMS 277

eDoc Box Directory (zip file)

NWCG Off-Highway Vehicle Typing Standard Request for Comment

Date: July 24, 2024
Contact: Mobile Fire Equipment Subcommittee 

The Mobile Fire Equipment Subcommittee has released Equipment Bulletin 24-002 NWCG Off-Highway Vehicle (OHV) Typing Standard - Request for Comment. This bulletin outlines the proposed NWCG OHV typing standard, as well as the business need for establishing the standard. Comments on the proposed standard will be accepted through August 15th using the comment form linked below.

References:

ETC-EB-2024-02: NWCG Off-Highway Vehicle (OHV) Typing Standard - Request for Comment

NWCG Off-Highway Vehicle (OHV) Typing Standard Comment Form

NWCG Standards for Airtanker Operations, PMS 514 - DRAFT

Date: July 18, 2024
Contact: National Interagency Aviation Committee 

A draft version of the new NWCG Standards for Airtanker Operations, PMS 514, is now available. The NWCG Standards for Airtanker Operations establishes the standards for dispatching, utilizing, and coordinating airtankers on wildland fires. As this is the first edition of these standards, the National Interagency Aviation Committee (NIAC) requests review and input into the 2025 final publication.

Please review and provide feedback by September 1st, 2024 for consideration. Feedback can be provided utilizing the NWCG Publication Review Form.

References:

NWCG Standards for Airtanker Operations, PMS 514 - DRAFT

NWCG Publications Review Form