Skip to main content

Proper Use of Trigger Points

 

The 10 Standard Firefighting Orders and the 18 Watch Out Situations, as referenced in the Incident Response Pocket Guide (IRPG), PMS 461, provide wildland firefighters with a set of consistent best practices and a series of scenarios to be mindful of when responding to a wildland fire.

Accurate situation awareness (SA) requires a constant reassessment of conditions (existing and potential) that may impact the safety and effectiveness of tactics. Monitor for the 18 Watch Out Situations and establish trigger points (in the form of operational or environmental limits) ahead of time.

Remember, trigger points are not decision-makers but serve as predetermined cues to prompt you to re-evaluate the current and potential situation and its associated risks. They help you to determine and implement the proper course of action.

The following items are considerations in your planning and discussion.

  • Use trigger points for preplanning. Do not wait until you are in the wrong place at the wrong time – with no time.
  • Trigger points should be based on measurable factors such as: ​
    • Relative Humidity (RH).
    • Winds.
    • Fire behavior.
    • Topographical boundaries.
    • Time constraints/time of day.
    • Time/distance to safety zones.
    • Loss of suppression resources.
    • Other operational considerations (e.g., firefighter fatigue, loss of lookouts or communication, weather change).
  • As you approach predetermined trigger points, go through the Risk Management Process to help you decide if a change in tactics is required:
    • Identify hazards.
    • Assess hazards.
    • Develop controls and make risk decisions.
    • Implement controls.
    • Supervise and evaluate. ​
  • Consider the following command/leadership responsibilities when changing tactics:
    • Communicate the changes to your subordinates, as well as to adjacent forces and up the chain of command.
    • Account for all your people.
    • Make sure everyone knows and follows the new plan. ​

 

 

Last Modified / Reviewed:


Have an idea or feedback?

Share it with the NWCG 6MFS Subcommittee
 


Follow NWCG on X and Facebook
 


 

NWCG Latest Announcements

WFSTAR 2025 Core Component Module Package and 2024 Fire Year in Review Now Available

Date: March 14, 2025
Questions?  Please contact:
Joe Schindel at mschindel@blm.gov
 

The 2025 Core Component Module Package for RT-130, Wildland Fire Safety Training Annual Refresher (WFSTAR) and the 2024 Fire Year in Review are now available on the NWCG website. The 2025 Core Component Module Package provides all content needed to deliver RT-130.

References:

2025 Core Component Module Package

2024 Fire Year in Review Module

NEW! NWCG Wildland Urban Interface Mitigation Field Guide, PMS 053

Date: March 12, 2025
Contact: Wildland Urban Interface Mitigation Committee

The NWCG Wildland Urban Interface Mitigation Field Guide, PMS 053 provides mitigation practitioners at all experience levels with recommendations on the most effective and efficient ways to accomplish mitigation work in communities at risk to wildfire damage or destruction. The content in this guide was written in coordination with the NWCG Standards for Mitigation in the Wildland Urban Interface, PMS 052.

References:

NWCG Wildland Urban Interface Mitigation Field Guide, PMS 053 

Updated, NWCG Standards for Wildland Fire Module Operations, PMS 430

Date: March 11, 2025
Contact: Fire Use Subcommittee
Wildland Fire Module Unit

The NWCG Standards for Wildland Fire Module Operations, PMS 430 standardizes procedures and expectations for Wildland Fire Modules (WFMs). These standards are to be used by staff, supervisors, specialists, and technicians for planning, administering, and conducting WFM operations. These standards will also be used as a measure of WFM qualifications, capabilities, and expected performance, for both Type 1 and Type 2 WFMs.

References:

NWCG Standards for Wildland Fire Module Operations, PMS 430

NEW! NWCG Standards for Airtanker Operations, PMS 514

Date: March 7, 2025
Contact: National Interagency Aviation Committee

The NWCG Standards for Airtanker Operations, PMS 514 establishes the standards for dispatching, utilizing, and coordinating airtankers on interagency wildland fires. These standards should be used in conjunction with the NWCG Standards for Aerial Supervision (SAS), PMS 505, NWCG Standards for Airtanker Base Operations (SABO), PMS 508, and any applicable agency plans.

References:

NWCG Standards for Airtanker Operations, PMS 514