Skip to main content

PMS 448

Flight Suit – Chest Size 36, Inseam 28 1/2” (S)

NFES #
000501
Category
Clothing
Updated
Storage and Shelf Life Checks
None

Initial Inspection/Disposal Criteria

  1. Inspect for holes, cuts, tears, burns, or torn seams. Inspect hook and pile fastener missing or that does not provide adequate closure, repair or dispose of. Inspect for broken zippers or missing sliders. Open and close the hook and pile fasteners to ensure they provide an adequate and secure closure. Open and close zipper to ensure smooth operation and secure closure.
  2. Return to stock if item is clean and all components are in good working condition.
  3. Refurbish if cleaning is the only refurbishment required.
  4. Dispose of item if any damage is found in the inspection process.

Refurbishing Procedures

A. Cleaning

  1. Follow the cleaning procedures described in the publication, Nomex®- Aramid Fiber -Laundering Guide (H71603).
    Additional information can be obtained by calling DuPont at 1–800–453–8527 or by writing:
    DuPont Advanced Fibers Systems
    Chestnut Run Plaza
    Laurel Run Building
    Wilmington, DE 19880-0705
  2. Abbreviated washing procedures from above publication:
    1. “Garments of NOMEX® should be washed separately from other articles to avoid contamination with lint of flammable fibers.”
    2. “Tests show that formulations designed for use at a temperature of 140 °F (60 °C) or less – such as high-surfactant, low-alkalinity products – adequately clean NOMEX® and provide the best fabric color retention.”
    3. “For heavily stained and oily garments of NOMEX®, a higher temperature wash formula may be required for adequate cleaning.”
    4. “Garments made of NOMEX® must be adequately rinsed to remove residual wash chemicals.”
    5. “In some instances, tumble dry conditioning is the only finishing necessary for garments of NOMEX®.”
    6. “…dry cleaning is an alternative method of removing heavy soil and may be preferable to repeated high-temperature washing.”
  3. If items are taken to vendor laundry facilities for refurbishment; ensure that they receive a copy of this refurbishment standard. The laundry facility must satisfy both the requirements as set by the manufacturer specification and the agreement made with the local agency.

B. Repairs

  • None

C. Test for performance

  • None

D. Repackaging

  • Local cache option

 

NWCG Latest Announcements

2025 Professional Reading Program

Date: February 18, 2025
Contact: Wildland Fire Leadership Development Program (WFLDP)

The Wildland Fire Leadership Development Program is announcing the 2025 Professional Reading list! The goal of the annual reading list is to promote the reading and discussion of the books throughout the year.

The five books chosen for this year are: Surf When You Can by Brett Crozier, Man’s Search for Meaning by Viktor E. Frankl, Elephant Company by Vicki Constantine Croke, Simply Managing by Henry Mintzberg, and Chop Wood Carry Water by Joshua Metcalf.

References:

Professional Reading Program

Task Group Volunteers Needed to Update the Property Loss or Damage Report, OF 289

Date: February 5, 2025
Contact: Julie Bennett, Incident Business Committee Chair

The Incident Business Committee (IBC) is requesting volunteers for a new task group to revise the 1981 version of the Property Loss or Damage Report, OF 289 and create an incident replacement job aid. The volunteers may be recruited from within or outside the Geographic Area Incident Business Committees.

References:

IBC Memorandum 25-02

IBC Correspondence

2025 Updates to the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1

Date: February 4, 2025
Contact: Incident and Position Standards Committee

The NWCG Incident and Position Standards Committee has updated the NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1. 

These updates address changes to incident position names and requirements for qualification, training, and experience. Updates related to the implementation of Complex Incident Management (CIM) are also included.  

The NWCG Wildland Fire Position Qualification Flowchart, PMS 308 has also been updated to reflect the recent changes.

References:

NWCG Standards for Wildland Fire Position Qualifications, PMS 310-1

NWCG Wildland Fire Position Qualification Flowchart, PMS 308

NWCG Memo: 2025-01 January 2025 Updates to the NWCG Standards for Wildland Fire Positions Qualifications, PMS 310-1

NWCG Equipment Technology Committee Releases Safety Warning: 25-001 Non-specification fire shelters

Date: January 15, 2025
Contact: Equipment Technology Committee

The Equipment Technology Committee (ETC) has released Safety Warning: 25-001 Non-specification fire shelters. Non-specification fire shelters claiming to meet Forest Service (FS) fire shelter specification 5100-606 were first found in February of 2023. As of September 2024, non-specification shelters are again being advertised and sold on the open market.

This Safety Warning outlines details and recommended procedures to purchase FS specification shelters made with materials and components that meet performance criteria and toxicity testing requirements outlined in FS Specification 5100-606. 

For additional information on identifying non-specification shelters, please view ETC Safety Warning 23-01.

References:

ETC Safety Warning 25-001: Non-specification fire shelters

NWCG Equipment Technology Committee

ETC Safety Warning 23-01