Storage and Shelf Life Checks
None

Initial Inspection/Disposal Criteria

  1. Inspect for holes, cuts, tears, or torn seams. Inspect for color change (yellow to white/pink) caused by exposure to heat. Dye sublimation is the result of heat baking the dye out of the fabric. Areas of fabric with dye sublimation do not affect the performance of the shirt. Charring (hard brittle fabric that will then form a hole) in association with sublimation will decrease the performance of the fabric and the item should be disposed of.
  2. Return to stock if item has no damage, is clean and in unused condition.
  3. Refurbish if item can be laundered and is repairable.
  4. Dispose of item if not economical to repair.

Refurbishing Procedures

A. Cleaning - DO NOT USE BLEACH TO CLEAN FABRIC.

  1. Follow the cleaning procedures described in the publication, Nomex®- Aramid Fiber -Laundering Guide (H71603).
    Additional information can be obtained by calling DuPont at 1–800–453–8527 or by writing:
    DuPont Advanced Fibers Systems
    Chestnut Run Plaza
    Laurel Run Building
    Wilmington, DE 19880-0705
  1. Abbreviated washing procedures from above publication:
    1. “Garments of NOMEX® should be washed separately from other articles to avoid contamination with lint of flammable fibers.”
    2. “Tests show that formulations designed for use at a temperature of l40 °F (60 °C) or less – such as high-surfactant, low-alkalinity products - adequately clean NOMEX® and provide the best fabric color retention.”
    3. “For heavily stained and oily garments of NOMEX®, a higher temperature wash formula may be required for adequate cleaning.”
    4. “Garments made of NOMEX® must be adequately rinsed to remove residual wash chemicals.”
    5.  “In some instances, tumble dry conditioning is the only finishing necessary for garments of NOMEX®.”
    6.  “…dry cleaning is an alternative method of removing heavy soil and may be preferable to repeated high-temperature washing.”
  2. If items are taken to vendor laundry facilities for refurbishment; ensure that they receive a copy of this refurbishment standard. The laundry facility must satisfy both--the requirements as set by the manufacturer specification and the agreement made with the local agency.

Nomex® Clothing Exposed to Poison Oak/Ivy/Sumac

RESEARCH

At the request of the National Support Cache Refurbishing Standards Committee, MTDC researched the practicality of laundering Nomex firefighting clothing that has been contaminated with urushiol oil (the allergen to which the body reacts) from poison oak/ivy/sumac exposure. Current cache practices range from normal washing procedures to disposal of shirts and pants that have known urushiol contamination.

A search of on-line sources didn’t produce any special care instructions beyond normal laundering. Some examples:

  • “All clothing should be laundered, and everything else that may be contaminated with urushiol should be washed thoroughly.” American Academy of Dermatology. 
  • “…be sure to wash your clothing promptly with detergent…” Mayo Clinic. 
  • “Washing clothes with ordinary laundry soap will remove urushiol.” Missouri Department of Conservation.

A phone conversation with Daniel Boelman, RN, BSN, Customer Service Manager with Zanfel Laboratories, Inc. also indicated no special treatment beyond normal laundering. (Zanfel produces a commercially available poison oak/ivy cream). Mr. Boelman recommended using vinyl gloves when handling contaminated clothing.

On 11/17/2008 the Forest Service filed a SAFENET Supplemental Corrective Action concerning poison oak reactions experienced by firefighters during the 2008 fire season in California. In that posting, it is recommended that “All clothing and equipment should be laundered immediately …A degreaser was recommended for helping to remove urushiol from clothing and equipment.”

RECOMMENDATION

MTDC recommends that fire clothing contaminated with urushiol oil be cleaned following normal Nomex laundering procedures. Extra care should be exercised when handling the contaminated clothing. Clearly labeled plastic bags should be used to separate contaminated clothing from other returned clothing. Commercial laundry personnel should wear long sleeves and vinyl gloves when handling contaminated clothing and dispose of any bags used for transporting the clothes to the laundering facility. As an extra precaution, supply cache and laundry workers could apply an over-the-counter skin-barrier product that contains bentoquatum (such as Ivy Block or Stokoguard) before handling contaminated clothing. Bentoquatum helps prevent urushiol from penetrating the skin. After exposure, workers’ clothes should be washed and gloves disposed of. 

B. Repair

  1. Mend holes, cuts, tears, burns, and torn seams by darning, patching, or by duplicating the original item.
  2. Replace damaged hook and pile fasteners with tape of same length, width, and quality.

C. Testing for Performance

  1. Inspect items after laundering to ensure all foreign matter and stains have been removed. If items fail second inspection spot treat problem areas or remove item from service.
  2. Test all replacement hook and pile fasteners after repairing.

D. Repackaging

  1. Lay the Shrouds with inside up, fold both sides towards middle, and fasten hook and pile fasteners.
  2. Recommended 20 EA in NFES #008064 carton (10” x 8” x 6”).

 

NWCG Latest Announcements

NWCG Equipment Technology Committee Releases Safety Warning: 25-001 Non-specification fire shelters

Date: January 15, 2025
Contact: Equipment Technology Committee

The Equipment Technology Committee (ETC) has released Safety Warning: 25-001 Non-specification fire shelters. Non-specification fire shelters claiming to meet Forest Service (FS) fire shelter specification 5100-606 were first found in February of 2023. As of September 2024, non-specification shelters are again being advertised and sold on the open market.

This Safety Warning outlines details and recommended procedures to purchase FS specification shelters made with materials and components that meet performance criteria and toxicity testing requirements outlined in FS Specification 5100-606. 

For additional information on identifying non-specification shelters, please view ETC Safety Warning 23-01.

References:

ETC Safety Warning 25-001: Non-specification fire shelters

NWCG Equipment Technology Committee

ETC Safety Warning 23-01

Paul Gleason Lead by Example Awards

Date: January 14, 2025
Contact: Leadership Committee

The NWCG Leadership Committee has awarded the 2023 Paul Gleason “Lead By Example” awards to individuals in the categories of Initiative and Innovation, Mentoring and Teamwork, and Motivation and Vision, as well as a Lifetime Achievement Award.

Congratulations to the awardees:

  • Sam Bowen, Superintendent of the Mark Twain Veteran Crew with the U.S. Forest Service.
  • Greg Titus, Zone Fire Management Officer for the St. Marks National Wildlife Refuge with U.S. Fish and Wildlife Service.
  • Renae Crippen, Manager of the Blue Mountain Interagency Dispatch Center with the U.S. Forest Service.
  • Eric Carlson, Instructor with OMNA International.

References:

Paul Gleason Lead by Example Award

Wildland Fire Leadership Development Program

Interview with Paul Gleason

Updated NWCG Standards for Water Scooping Operations, PMS 518

Date: December 19, 2024
Contact: Water Scooper Operations Unit

The NWCG Standards for Water Scooping Operations, PMS 518 establishes the standards for dispatching, utilizing, and coordinating water scooping aircraft on interagency wildland fires. These standards should be used in conjunction with the NWCG Standards for Aerial Supervision (SAS), PMS 505, and any local, state, or geographic/regional water scooping plans.

References:

NWCG Standards for Water Scooping Operations, PMS 518

Updated NWCG Standards for Aerial Supervision, PMS 505

Date: December 19, 2024
Contact: Interagency Aerial Supervision Subcommittee

The Interagency Aerial Supervision Subcommittee has updated the NWCG Standards for Aerial Supervision, PMS 505. PMS 505 establishes standards for aerial supervision operations for national interagency wildland fire operations. 

References:

NWCG Standards for Aerial Supervision, PMS 505