Bag – Slingable, Water, 360 GL, Non-Potable

NFES #
006021
Category
Water Handling
Updated
Storage and Shelf Life Checks
None

Initial Inspection/Disposal Criteria

  1. Visually inspect for missing components, or need for repair such as: straps, hoses, spigot, cap, and gasket.
  2. Return to stock if in unused condition.
  3. Refurbish if dirty or need repair.
  4. Dispose of item if it fails inspection and/or is damaged beyond repair.

Refurbishing Procedures

A. Cleaning

  1. Clean exterior of tank thoroughly with filler cap attached.
  2. Support or hang tank with spigot closed, remove cap and fill with water to rinse out tank.
  3. Replace cap and shake bag vigorously until all foreign matter is removed.
  4. Drain completely through hose and spigot.
  5. Invert bag after removing cap, open spigot and empty as much water as possible.
  6. Let dry inverted for 1 hour in sun, if possible.

B. Repair

  1. Fill with air and look for leaks, visually inspect bags for rips, tears, or obvious defects.
  2. Use a black permanent marker to indicate damage, keeping all markings simple and professional.
  3. In a well ventilated area clean area around damaged spot with lacquer thinner or other suitable cleaner.
  4. Apply suitable glue (manufacturer’s recommendation) to both surfaces (patch and tank).
  5. Let dry until tacky.
  6. Place patch on damaged area and apply pressure with roller or suitable device for at least 1 minute.
  7. Repair or replace any damaged components.
  8. Ensure bags are stenciled with NFES number and “non-potable” or “suppression use only”.

C. Testing for Performance

  1. Re-inspect any patches or repairs.
  2. Fill with air to test for leaks.

D. Repackaging

  • Ensure that tank is stenciled visibly with the words “NON-POTABLE” or SUPPRESSION USE ONLY” and proper NFES # is stenciled on tank.
    • Use NFES #008070 carton (18” x 15” x 5.5”) for NFES #000426.
    • For NFES #006017 and #006021, use local cache option for carton.

 

NWCG Latest Announcements

NWCG Equipment Technology Committee Releases Safety Warning: 25-001 Non-specification fire shelters

Date: January 15, 2025
Contact: Equipment Technology Committee

The Equipment Technology Committee (ETC) has released Safety Warning: 25-001 Non-specification fire shelters. Non-specification fire shelters claiming to meet Forest Service (FS) fire shelter specification 5100-606 were first found in February of 2023. As of September 2024, non-specification shelters are again being advertised and sold on the open market.

This Safety Warning outlines details and recommended procedures to purchase FS specification shelters made with materials and components that meet performance criteria and toxicity testing requirements outlined in FS Specification 5100-606. 

For additional information on identifying non-specification shelters, please view ETC Safety Warning 23-01.

References:

ETC Safety Warning 25-001: Non-specification fire shelters

NWCG Equipment Technology Committee

ETC Safety Warning 23-01

Paul Gleason Lead by Example Awards

Date: January 14, 2025
Contact: Leadership Committee

The NWCG Leadership Committee has awarded the 2023 Paul Gleason “Lead By Example” awards to individuals in the categories of Initiative and Innovation, Mentoring and Teamwork, and Motivation and Vision, as well as a Lifetime Achievement Award.

Congratulations to the awardees:

  • Sam Bowen, Superintendent of the Mark Twain Veteran Crew with the U.S. Forest Service.
  • Greg Titus, Zone Fire Management Officer for the St. Marks National Wildlife Refuge with U.S. Fish and Wildlife Service.
  • Renae Crippen, Manager of the Blue Mountain Interagency Dispatch Center with the U.S. Forest Service.
  • Eric Carlson, Instructor with OMNA International.

References:

Paul Gleason Lead by Example Award

Wildland Fire Leadership Development Program

Interview with Paul Gleason

Updated NWCG Standards for Water Scooping Operations, PMS 518

Date: December 19, 2024
Contact: Water Scooper Operations Unit

The NWCG Standards for Water Scooping Operations, PMS 518 establishes the standards for dispatching, utilizing, and coordinating water scooping aircraft on interagency wildland fires. These standards should be used in conjunction with the NWCG Standards for Aerial Supervision (SAS), PMS 505, and any local, state, or geographic/regional water scooping plans.

References:

NWCG Standards for Water Scooping Operations, PMS 518

Updated NWCG Standards for Aerial Supervision, PMS 505

Date: December 19, 2024
Contact: Interagency Aerial Supervision Subcommittee

The Interagency Aerial Supervision Subcommittee has updated the NWCG Standards for Aerial Supervision, PMS 505. PMS 505 establishes standards for aerial supervision operations for national interagency wildland fire operations. 

References:

NWCG Standards for Aerial Supervision, PMS 505